TAYBO TB-CWM | Dual-Source Chiller for AI Data Centers

TAYBO TB-CWM | Dual-Source Chiller for AI Data Centers

Meet the TAYBO TB-CWM, an air-cooled, dual-source chiller designed for modular and AI data centers. As each new block of compute adds heat, this video shows how the TB-CWM combines gravity heat-pipe free cooling with mechanical refrigeration in a single 40-ft high cube module. An exploded view walks through the unit layer by layer: an axial fan deck with 16 fans, 8 banks of V-bank heat exchangers, and hydronic heat exchangers and refrigerant pipework connected to an oil-free centrifugal compressor. At operating speed, a thin gas film supports the compressor shaft, so the air bearings need no lubricating oil. In cool weather, the gravity heat-pipe circuit works as a two-phase thermosyphon: refrigerant absorbs heat from the return fluid, rises as vapor, condenses in the outdoor coil and flows back under gravity. When this circuit meets the load, the compressor can stop while fans and pumps keep running. As outdoor temperatures rise, mechanical cooling takes over to hold the supply temperature target. The video also shows how the TB-CWM connects to GPU liquid cooling, from cold plates through the CDU to outdoor air. Warmer facility supply temperatures can extend free-cooling hours, reducing compressor runtime to help improve site PUE, while dry heat rejection avoids water evaporation at the chiller to help lower site WUE. The reference model TB-CWM1750C-800F delivers 1.75 MW of mechanical cooling or 800 kW of free cooling at ΔT ≥ 15°C, and a single module can be configured for up to 2 MW (about 569 US RT) of mechanical cooling. Actual capacity depends on the selected operating point and site conditions. Watch the full video to see how TAYBO builds cooling that scales with compute, with energy and water in mind.

View details
TAYBO Mini SyncreticBlock | All-in-One Micro Data Center

TAYBO Mini SyncreticBlock | All-in-One Micro Data Center

Explore TAYBO Mini SyncreticBlock, a compact, all-in-one micro data center solution built around a building-block concept. It integrates UPS, power distribution, cooling, monitoring and fire protection within a single cabinet, providing an integrated infrastructure environment to support IT equipment at small businesses and distributed sites. Through cabinet breakdown and airflow animations, this video explains the integrated systems and cooling process. A bottom-mounted air conditioner supplies cold air upward through the internal cold-air passage to cool rack-mounted servers. Heated air returns through the hot-air passage to the air conditioner at the bottom. Separately, a top-mounted condenser rejects heat through fans, illustrating the distinction between internal air circulation and condenser heat rejection. The enclosed cabinet design and transport casters make the unit easier to move and position. Bringing cooling and related infrastructure into the cabinet reduces the need for separately arranged air supply outlets and hot and cold aisles. The video also shows multiple cabinets positioned side by side. For operations and maintenance, the presentation highlights management and servicing at the individual-cabinet level. Local and remote monitoring, together with centralized management through a higher-level platform, help operators oversee equipment across multiple branch sites. Featured applications include small and medium-sized businesses; branch locations in utilities, telecommunications, finance, broadcasting and retail; enterprise, government, education and healthcare sites; and edge data centers. Watch the video for a closer look at the system integration, cooling airflow, installation features, maintenance approach and monitoring capabilities of Mini SyncreticBlock.

View details
TAYBO GHP Free-Cooling Liquid Cooling Unit | Gravity Heat Pipe Technology

TAYBO GHP Free-Cooling Liquid Cooling Unit | Gravity Heat Pipe Technology

Discover TAYBO’s third-generation GHP free-cooling liquid cooling unit, which combines gravity heat pipe technology with a conventional liquid cooling system. This video introduces the unit’s configuration, operating principle and design features for temperature control in energy storage installations and data centers. The animation identifies the evaporation section, condensation section, plate heat exchanger and connecting pipework. Heat is transferred through evaporation, condensation and gravity-assisted liquid return. The free-cooling arrangement shares the plate heat exchanger and fans with the main system, while the heat pipe and compressor refrigeration circuits remain independent. When the system’s return liquid is warmer than the ambient air and suitable conditions are available, the heat pipe system can make use of natural cooling. For servicing, the presentation shows a built-in, semi-enclosed venting and liquid storage tank for filling and air removal. It also introduces a centrifugal fan arrangement, explaining the design approach to maintenance access and the fan’s operating environment. Site layout is another focus. Container and airflow illustrations explain the intended role of the outlet direction in limiting hot-air interaction between units. The video also presents a wide operating-voltage range, compatibility with different supply frequencies, and an optional soundproof cover used with the centrifugal fans. Watch the full video for an overview of the integrated design and its proposed use in energy storage sites and data centers, including locations with noise-control requirements. Free-cooling availability and energy savings depend on climate, load and operating conditions; project selection should be assessed against the applicable product specifications and site requirements.

View details
TAYBO | Ultra-Quiet Thermal Management for C&I Energy Storage

TAYBO | Ultra-Quiet Thermal Management for C&I Energy Storage

Discover TAYBO's ultra-quiet thermal management concept for industrial and commercial energy storage. This video introduces an integrated arrangement combining cabinet heat dissipation, heating and cooling modules, perforated air pipes and thermally conductive battery PACKs. Exterior views, exploded assemblies and animated operating sequences explain how these elements work together. The heat-rejection sequence shows compressed refrigerant entering the cabinet-wall heat-dissipation structure. Outside air enters the lower opening, rises as it warms within the wall passage and leaves through the upper opening. This natural-convection arrangement eliminates the traditional condenser fan, addressing a source of system noise and reducing fan-related maintenance work. For battery temperature management, the presentation illustrates the relationship between the thermal module, connecting pipes and battery PACKs. It also introduces the nano thermally conductive PACK concept and the integration of heat-dissipation structures with the cabinet. The enclosure design is presented as part of the approach to limiting the influence of external dust, rainwater and heat. The video goes on to introduce high-voltage DC refrigeration and temperature control, highlighting the design objective of reducing auxiliary power demand. Installation, commissioning and maintenance considerations form another part of the product overview. Cabinet and heat-exchanger examples, together with manufacturing footage, conclude the presentation of TAYBO's design and production capabilities for industrial and commercial energy storage applications.

View details
TAYBO | Ultra-Quiet Liquid Cooling for C&I Energy Storage

TAYBO | Ultra-Quiet Liquid Cooling for C&I Energy Storage

Explore TAYBO's ultra-quiet liquid-cooling solution for industrial and commercial energy storage. This video addresses noise, installation space and localized heat accumulation through a design combining liquid cooling, internally mounted fans and cabinet heat-dissipation ducts. Animated views explain both the cooling circuits and the equipment layout. Inside the refrigeration unit, the compressor pressurizes the refrigerant before heat is rejected through the condenser. After cooling and throttling, the refrigerant enters a plate heat exchanger to absorb heat from the coolant. A water pump circulates the cooled liquid to the battery PACK for cell cooling and back to the unit, completing a closed loop. For heat rejection, an internal high-static-pressure centrifugal fan directs warm air through ducts along the cabinet walls and out through the top. The presentation compares this arrangement with conventional axial condenser fans, explaining how fan placement and the exhaust path form part of the noise-control design. The video also illustrates side-by-side and back-to-back cabinet arrangements. Top exhaust reduces reliance on rear discharge space and is presented as a way to improve site utilization and limit heat accumulation around the equipment. Watch for a visual overview of the compressor, condenser, plate heat exchanger, water pump, internal fan and battery PACK connections. The presentation introduces TAYBO's approach to liquid-cooling integration, low-noise thermal management and customized cooling solutions for industrial and commercial energy storage manufacturers.

View details
TAYBO Smart Mushroom Growing Container | Climate and Fresh Air Control

TAYBO Smart Mushroom Growing Container | Climate and Fresh Air Control

How can a mushroom production facility bring climate control, ventilation and everyday operation into one integrated enclosure? This video introduces TAYBO's smart mushroom growing container. Product footage, system animations and controller displays explain a solution that combines air conditioning, fresh air, humidification and air treatment for mushroom cultivation. The climate-control section shows a controller monitoring the container's temperature in real time and adjusting operation according to the target setting. Cooling, heating and humidification are presented as coordinated functions intended to maintain suitable growing conditions. Animated airflow helps explain the operating concept inside the enclosure. The fresh-air section follows a centrifugal fan bringing outdoor air into the container while stale air is discharged. The video describes filtration, sterilization and disinfection functions for incoming air. Ducted air delivery is used to reduce direct cold airflow onto the mushrooms, linking ventilation, air treatment and distribution within the growing space. Resource-use features include heat recovery in the fresh-air system and collection of air-conditioning condensate for reuse in humidification. The container can also be arranged side by side or back to back. These design elements illustrate the product's approach to energy, water and site utilization within a mushroom production layout. An external touchscreen provides an interface for checking information, changing settings and monitoring operation. The video also introduces mobile-app parameter import, power-off memory and automatic startup. Watch to understand the container's system configuration, airflow principles and operating interface if you are exploring mushroom facilities, container-based cultivation or agricultural environmental control.

View details
TAYBO | Dual-Source Cooling Retrofit for Data Centers

TAYBO | Dual-Source Cooling Retrofit for Data Centers

Explore TAYBO's dual-source cooling retrofit concept for data centers. This video focuses on the cooling energy demands of existing facilities and introduces the addition of a natural cooling source alongside the original refrigeration system. Equipment and piping animations provide an overview of how the two sources are brought together within the cooling arrangement. The illustrated system combines heat exchangers, a dual-source CDU, a control system and closed-circuit cooling towers. By showing the connections between these components, the presentation explains the overall heat-transfer path and how the additional cooling source connects with the data center cooling infrastructure. Natural cooling is a central theme of the presentation. The video also includes a summer operating scenario, illustrating how the combined arrangement is intended to support the cooling requirements of the facility. The animations help viewers follow the system layout, understand the role of each major component and see the relationship between cooling-source utilization and operational energy demand. For retrofit planning, the presentation emphasizes working with the existing system rather than extensively rebuilding it. It offers a visual introduction for facility operators and project teams exploring data center cooling optimization, natural cooling utilization and energy-saving upgrades. Watch the video for an overview of the equipment configuration, interconnected cooling circuits and control concept behind this dual-source approach.

View details
TAYBO ELF MicroBlock | Fluorinated Fluid Cooling for Data Centers

TAYBO ELF MicroBlock | Fluorinated Fluid Cooling for Data Centers

Explore TAYBO ELF MicroBlock, a cabinet-level data center cooling solution using a fluorinated cooling fluid. The video introduces the indoor cabinet, bottom-mounted cooling module and outdoor unit, alongside integrated infrastructure functions including UPS power protection, power distribution, cooling, monitoring and fire protection. The animation distinguishes two heat-transfer paths. Inside the cabinet, cold air moves upward from the bottom cooling module through the cold-air passage to the rack-mounted servers. Warm air returns through the hot-air passage to the module. In a separate circuit, the cooling fluid circulates through pipework between the cabinet module and outdoor unit to transfer heat outdoors. This is an air-to-liquid heat-exchange arrangement, rather than a demonstration of server immersion. The outdoor unit includes compressor refrigeration components and a free-cooling coil. The presentation explains how natural cooling can reduce compressor operating time when outdoor temperatures and the available temperature difference are suitable. Other sections examine the rack-mounted cooling module, enclosed cabinet, internal hot and cold passages, and grouped cabinet arrangements. The video also discusses the fluid’s electrical insulation and thermal stability, together with installation, maintenance, fire compartmentation and mutual-backup design concepts. Application examples include telecommunications, finance, healthcare, government and enterprise data centers. The closing section also mentions flexibility between air and liquid cooling configurations. Watch the full video to follow the path from cabinet airflow to outdoor heat rejection. Energy performance, free-cooling availability and backup capacity should be evaluated for the project’s climate, load, equipment configuration and design conditions.

View details
TAYBO Plate-Less Cooling System | Thermal Management for Energy Storage

TAYBO Plate-Less Cooling System | Thermal Management for Energy Storage

How can an energy storage cooling system simplify its battery-side architecture while managing cell temperatures? This video introduces TAYBO's plate-less cooling system for energy storage. Exploded views and operating animations explain a design that combines a liquid cooling supply with air-based heat exchange around the battery cells. The illustrated configuration removes battery cooling plates, secondary and tertiary cooling pipelines, and separate dehumidifying air-conditioning units inside the cabinet. A liquid cooling unit and primary liquid cooling pipeline remain part of the system. Reducing components around the batteries is intended to free vertical space and simplify the container's internal arrangement. The operating sequence follows coolant from the liquid cooling unit to thermal modules beneath the battery clusters. Heat exchangers and high-static-pressure fans in these modules cool the air. A central air duct then delivers that air to the nano thermal packs between the cells, showing how the liquid circuit, heat exchange and airflow work together. The video also presents thermal-pack and airflow features intended to support more uniform heat exchange and reduce temperature differences within a battery pack. Further sections discuss temperature response, condensation management, cooling-fluid selection, and the potential value of a simpler architecture for material use, installation and system integration. Wind and solar energy storage scenes place the concept in its application context, while laboratory and manufacturing footage introduce TAYBO's wider thermal management work. Watch for a visual explanation of the system layout and cooling path, particularly if you work with battery thermal management or containerized energy storage integration.

View details