Mechanical refrigeration mode
Reference cooling capacity 1,750 kW; reference input power 440 kW; calculated COP about 3.98.

TB-CWM1750C-800F with oil-free air-bearing compressors and gravity heat-pipe cooling
The TAYBO TB-CWM1750C-800F dual-source chiller is designed for data center cooling. It integrates oil-free air-bearing compressor mechanical refrigeration with gravity heat-pipe free cooling in a single unit. The system selects the operating mode based on outdoor conditions—providing mechanical cooling when required and using free cooling to cut compressor runtime when conditions allow. The unit combines a V-coil heat exchanger, axial fans, compressors, and controls in one package to simplify equipment integration for integrated cooling plants and data center cooling systems.

Reference cooling capacity 1,750 kW; reference input power 440 kW; calculated COP about 3.98.

When ambient conditions allow, refrigerant transfers heat to outdoor air by gravity circulation with compressors off. At a temperature difference ΔT of at least 15°C, free-cooling rated capacity is 800 kW, helping cut mechanical cooling runtime and energy use.
During normal operation the rotating shaft is supported by an air film—no bearing lubricant and no bearing contact.
Both cooling modes are integrated in a single unit and can run accordi
Under suitable conditions, heat is rejected through refrigerant gravity circulation with compressors shut down.
V-coil heat exchanger, axial fans, compressors, and controls in a coordinated one-piece layout.
DN250 bottom water connections, RS485 communications, and IP55 rating for easy tie-in to project cooling and monitoring systems.

Mechanical refrigeration and free cooling in a single unit
Cut compressor runtime and cooling energy when ambient conditions allow
Oil-free air-bearing design needs no bearing lubricant and reduces related lubrication system needs
One-piece layout simplifies equipment integration and supports integrated cooling plant arrangements
Standard water and communication interfaces simplify connection to project cooling and monitoring systems

Integrates cooling sources, pumps, piping, and controls to support phased data center expansion.

Integrated 374 kW air- and liquid-cooled load bank for data-center cooling validation. Combines 342 kW of adjustable liquid load (4 × 85.5 kW modules) with 32 kW of adjustable air load to simulate mixed thermal loads. Supports stepped and full-load commissioning of coolant loops and heat rejection, with monitoring of flow, pressure, temperature, voltage, current and power. Local HMI, remote/group control, alarms, trend logging and data export support test operations. Configurable test coverage for VR200, NVIDIA NVL72 and NVL144 systems.